Zoom In
        
        
            Zoom Out
        
        
            Enlarge
        
    
    *Product images are for illustrative purposes only and may differ from the actual product.
    
     
    
    CCW Instrumentation; Ind. & Overall Shield; PVC Jacket; 90°C
    
    
        
    Continuously Corrugated Welded Cable – CCW® 
PVC/Nylon - PVC Jackets 
Pairs & Triads – Individual & Overall Shields 
90°C – 600 Volt
 
        
                
                
                    
                    
                
         
        
                
                
                    
                    
                
         
        
 
    
     
    
        
            
                                
                                
                                
                                
                                
                                
                                
                                
                                
                                                
    
        
            
                | Construction | 
        
        
                
                    | Category Conductor Description | Bare, annealed copper conforming to ASTM B3 and stranded in accordance with ASTM B8 (Class B) | 
                
                    | Category Insulation Description | Flame-retardant Polyvinyl Chloride (PVC) insulation and nylon covering, rated 90°C per UL Standard 83   
Color Code: ICEA Method 1 | 
                
                    | Individual Shield | Isolated and individually twisted pairs or triads with an aluminum/polyester tape shield providing 100% coverage
Drain wire | 
                
                    | Overall Shield | Aluminum/polyester tape shield providing 100% coverage
Drain wire | 
                
                    | Inner Jacket | Flame retardant Polyvinyl Chloride (PVC) per UL 1569, black 
Low temp performance meets ASTM D746 brttleness temp at or below -40°C
Nylon ripcord | 
                
                    | Armor | Impervious, continuously corrugated and welded aluminum per UL 1569 & 2225 
Meets grounding requirements of NEC Article 250 | 
                
                    | Overall Jacket | Flame-retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC) per UL Standards 1569, black
Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C | 
        
    
                                 
                                
                                                
        
                            - 
                                For use as instrumentation tray cable on circuits rated 150V or less and 5 amps or less in accordance with NEC article 727   
                            
- 
                                Recognized for use in Class I, II, and III, Divisions 1 and 2; or Class 1, Zones 1 and 2 hazardous locations per NEC articles 501, 502, 503 and 505   
                            
- 
                                Installed indoors and outdoors, in wet or dry locations, in a raceway, as aerial cable on a messenger, in cable trays, or for direct burial   
                            
- 
                                Recognized for use on fixed or floating offshore petroleum facilities as recommended by American Petroleum Institute
                            
 
                                
                                                
        
                            - 
                                UL Type MC-HL   
                            
- 
                                UL 83, 1569, 2225, 1309 and 1581   
                            
- 
                                IEEE 1202 available upon request
                            
 
                                
             
         
     
 
    
Part Number Table
    
        
            
                
                | Part # | Houston Wire & Cable | Gauge | Pairs | Triads | Nominal OD over Core | Nominal OD over Armor | Nominal OD Overall | Material Weight (Lbs./M') | 
                
                    | XL41812 | - | 18 | 12 | - | .780 | 1.00 | 1.105 | 560 | 
                
                    | XL41824 | - | 18 | 24 | - | 1.08 | 1.39 | 1.49 | 969 | 
                
                    | XL41602 | HW305.pdf | 16 | 2 | - | .450 | .670 | .780 | 246 | 
                
                    | XL41604 | HW305.pdf | 16 | 4 | - | .560 | .800 | .910 | 346 | 
                
                    | XL41608 | HW305.pdf | 16 | 8 | - | .700 | .930 | 1.04 | 502 | 
                
                    | XL41612 | HW305.pdf | 16 | 12 | - | .850 | 1.11 | 1.22 | 670 | 
                
                    | XL41624 | HW305.pdf | 16 | 24 | - | 1.12 | 1.42 | 1.53 | 1336 | 
                
                    | XL41636 | - | 16 | 36 | - | 1.37 | 1.69 | 1.82 | 2184 | 
                
                    | XL51604 | HW305.pdf | 16 | - | 4 | .610 | .840 | .950 | 428 | 
                
                    | XL51608 | HW305.pdf | 16 | - | 8 | .820 | 1.06 | 1.17 | 694 | 
                
                    | XL51612 | 4333-1612GRDXHL | 16 | - | 12 | .980 | 1.24 | 1.35 | 958 | 
        
    
        Note: The data shown are approximate and subject to standard industry and manufacturer tolerances
General Cable CCW® is a registered trademark of General Cable