    CCW Instrumentation - Overall Shield - 90°C
    
    
        
    UL Type MC-HL, PVC/Nylon   
600V, 90°C   
Cable Tray Use, Sunlight-Resistant, Direct Burial, UL Marine Shipboard Cable, ABS CWCMC
 
        
                
                
                    
                    
                
         
 
    
     
    
        
            
                                
                                
                                
                                
                                
                                
                                
                                                
    
        
            
                | Construction | 
        
        
                
                    | Category Conductor Description | Bare, annealed copper conforming to ASTM B3 and Stranded in accordance with ASTM B8 (Class B) | 
                
                    | Category Insulation Description | Flame-retardant Polyvinyl Chloride (PVC) and nylon covering, rated 90°C per UL Standard 83   
Color Code: ICEA Method 1 | 
                
                    | Overall Shield | Aluminum/polyester tape shield providing 100% coverage
Stranded tinned copper drain wire, same size as insulated conductors | 
                
                    | Inner Jacket | Flame retardant Polyvinyl Chloride (PVC) per UL 1569, Black
Low temp performance meets ASTM D746 brittleness temp at or below -40°C 
Nylon ripcord | 
                
                    | Armor | Impervious, continuously corrugated and welded aluminum per UL 1569 & 2225 
Meets grounding requirements of NEC Article 250 | 
                
                    | Overall Jacket | Flame-retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC) per UL Standards 1569, black
Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C | 
        
    
                                 
                                
                                                
        
                            - 
                                For use in Class 1 remote-control and signal circuits in accordance with NEC Article 725   
                            
- 
                                Recognized for use in Class I, II, and III, Divisions 1 and 2; or Class I, Zones 1 and 2 hazardous locations per NEC articles 501, 502, 503 and 505
                            
 
                                
             
         
     
 
    
Part Number Table
    
        
            
                
                | Part # | Houston Wire & Cable | Gauge | Pairs | Triads | Nominal OD over Core | Nominal OD over Armor | Nominal OD Overall | Material Weight (Lbs./M') | 
                
                    | XL21601 | HW305.pdf | 16 | 1 | - | .350 | .530 | .640 | 178 | 
                
                    | XL51601 | HW305 1601T | 16 | - | 1 | .350 | .530 | .640 | 180 | 
        
    
        Note: The data shown are approximate and subject to standard industry and manufacturer tolerances