    CCW Instrumentation - Ind. & Overall Shield - 105°C
    
    
        
    Continuously Corrugated Welded Cable - CCW® 
PVC/Nylon Insulation - PVC Jackets 
Pairs & Triads - Individual & Overall Shields 
105°C - 300 Volt - UL Type ITC-HL/PLTC
 
        
        
                
                
                    
                    
                
         
 
    
     
    
        
            
                                
                                
                                
                                
                                
                                
                                
                                
                                
                                                
    
        
            
                | Construction | 
        
        
                
                    | Category Conductor Description | Bare, annealed copper conforming to ASTM B-3 and stranded in accordance with ASTM B8 (Class B) | 
                
                    | Category Insulation Description | Flame-retardant Polyvinyl Chloride (PVC) and nylon covering, rated 105°C per UL Standard 13 & 2250   
Color Code: ICEA Method 1 | 
                
                    | Individual Shield | Aluminum/polyester tape with 100% coverage
Drain wire | 
                
                    | Overall Shield | Aluminum/polyester tape shield providing 100% coverage
Drain wire | 
                
                    | Inner Jacket | Flame-retardant Polyvinyl Chloride (PVC) per UL Standards 13 and 2250
Low temperature performance meets ASTM D746 brittleness temperature at or below 40°C
Nylon rip cord to facilitate jacket removal | 
                
                    | Armor | Impervious, continuously corrugated and welded aluminum per UL 1569 
Meets grounding requirements of NEC Article 250 | 
                
                    | Overall Jacket | Flame-retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC) per UL Standards 13 and 2250
Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C | 
        
    
                                 
                                
                                                
        
                            - 
                                For use as Power Limited Tray Cable on circuits rated 150V or less and 5 amps or less in Class 2 or Class 3 circuits in accordance with NEC Article 725   
                            
- 
                                For use as instrumentation tray cable on circuits rated 150V or less and 5 amps or less in accordance with NEC article 727   
                            
- 
                                Recognized for use in Class I, II, and III, Divisions 1 and 2; or Class 1, Zones 1 and 2 hazardous locations per NEC articles 501, 502, 503 and 505   
                            
- 
                                Installed indoors and outdoors, in wet or dry locations, in a raceway, as aerial cable on a messenger, in cable trays, or for direct burial   
                            
- 
                                Recognized for use on fixed or floating offshore petroleum facilities as recommended by American Petroleum Institute
                            
 
                                
                                                
        
                            - 
                                UL Type PLTC and ITC-HL   
                            
- 
                                UL 13, 2250, 1569, 1309, and 1581   
                            
- 
                                IEEE 1202 available upon request
                            
 
                                
             
         
     
 
    
Part Number Table
    
        
            
                
                | Part # | Houston Wire & Cable | Gauge | Pairs | Triads | Nominal OD over Core | Nominal OD over Armor | Nominal OD Overall | Material Weight (Lbs./M') | 
                
                    | XL31602 | HW304 1602P | 16 | 2 | - | .440 | .670 | .780 | 268 | 
                
                    | XL31604 | HW304 1604P | 16 | 4 | - | .520 | .710 | .820 | 403 | 
                
                    | XL31608 | HW304.pdf | 16 | 8 | - | .690 | .930 | 1.04 | 528 | 
                
                    | XL31612 | HW304 1612P | 16 | 12 | - | .810 | 1.06 | 1.17 | 783 | 
                
                    | XL31624 | HW304 1624P | 16 | 24 | - | 1.10 | 1.37 | 1.48 | 1628 | 
                
                    | XL61604 | HW304 1604T | 16 | - | 4 | .580 | .800 | .910 | 378 | 
                
                    | XL61608 | - | 16 | - | 8 | .790 | 1.02 | 1.13 | 621 | 
                
                    | XL61612 | - | 16 | - | 12 | .950 | 1.19 | 1.30 | 879 | 
        
    